Optical Fibre and Copper Cabling Systems

Products

Warren & Brown’s extensive telecommunications product range provides a complete solution for most applications in Carrier, Data Centre, Industrial and Enterprise cabling markets.

Warren & Brown’s Hypaconnect Integrated Cabling Solution (ICS) is an advanced structured cabling infrastructure solution that allows for various applications to be successfully operated over a single cable network including  voice, data, CCTV, Access Control, Automation, A/V and many others.

Included in Warren and Brown’s product range are optical fibre components such as our ducting raceway, patchcords, patch panels, Optical distribution frames (ODF) and other FTTH products. Copper cabling components include various CAT6, CAT6A, CAT7 patch panels, patch cords, LAN cable and other cable management items.

Showing all Products

RJ45 CATEGORY 6A CONNECTOR (SHIELDED)

The new field assembly MFP8 Cat6A is the number one choice whenever efficient and reliable connections are needed without major expense or effort, whether for classic cabling systems in ofïce buildings, data centers, in industry or for home cabling systems. Needless to say, it also supports High Power over Ethernet Plus (PoE+).

MFP8 Cat6A: For new freedom unstructured cabling

  • Can be assembled in 60 seconds without any special tools
  • Optimised for the field, including demanding applications
  • Suitable for cabling in office buildings, data centres, industrial facilities and home networks
  • Supreme reliability
  • Secure transmission even with outside interference
  • Ideal for network repairs, special length and extensions
Part numberShort nameType
TGJ00026A2110MFP8 T568 A Category 6Ablister package (10 pcs.)
TGJ00026A2111MFP8 T568 B Category 6Ablister package (10 pcs.)

 

RJ45 CATEGORY 6A CONNECTOR (UNSHIELDED)

The UFP8 Cat6A is the RJ45 plug for time-saving and efficient on-site assembly for all networks, from Voice right through to 10 Gigabit Ethernet. It can be assembled on all standard types of cable in just 60 seconds and no special tools are required.

57

 

Part numberRemarksType

TGJ00026A3110

AWG 24/1-23/1, AWG 27/7-23/7

blister package (10 pcs.)

TGJ00026A3111

AWG 24/1-23/1, AWG 27/7-23/7

blister package (10 pcs.)

TGJ00026A3112AWG 23/1-22/1, AWG 23/7-22/7

blister package (10 pcs.)

TGJ00026A3113AWG 23/1-22/1, AWG 23/7-22/7

blister package (10 pcs.)

CATEGORY 6 PATCH PANEL (UNSHIELDED, RJ45)

Part Number: TC402-41 – for 24 ports

Part Number: TC402-42 – for 48 ports


The HypaConnect HY series category 6 UTP Patch panel is easy to install and terminate in any network environment. The rear cable support bar provides a tie down and cable management point for LAN cable and the front patching field contains a labelling area for identifying connections. Available as either a 1RU, 24 Port or 2RU, 48 port versions, the HY patch panel series provides great flexibility for your network. This patch panel is suitable for unshielded cable (U/UTP), which is terminated onto the patch panel using a standard IDC termination tool.

CATEGORY 6A PATCH PANEL (UNSHIELDED, MODULAR, RJ45)

Part Number: TC402-43 (for 24 ports)

Part Number: TC402-45 (for 48 ports)


The HypaConnect HY series unshielded modular patch panel is easy to install in any network environment. The rear cable support bar provides a tie down and cable management point for LAN cable and the front patching field contains a labelling area for identifying connections. These patch panels are unloaded and suit the HY series category 6A unshielded modular jacks, which are ordered separately.

These patch panels are provided with all mounting hardware.

CATEGORY 6A PATCH PANEL (SHIELDED, MODULAR, RJ45)

Part Number: TC402-44 (for 24 ports), TC402-46 (for 48 ports)


The HypaConnect HY series shielded modular patch panel is easy to install in any network environment. The rear cable support bar provides a tie down and cable management point for LAN cable and the front patching fields contain a labelling area for identifying connections. These patch panels are unloaded and suit the HY series category 6A shielded modular jacks, which are ordered separately.

These patch panels are provided with all mounting hardware.

ANGLED MODULAR PATCH PANELS

Part Numbers: TC402A0101 (for 24 ports)

Part Number: TC402A0201 (for 48 ports)


WBT’s new angled modular patch panels provide an efficient and effective way to manage and route patch cords and cables. These angled patch panels are used to mount CAT6A jacks or CAT6 couplers. The angled faceplates route the patch cords to the side of the rack, generally feeding them into vertical cable managers which minimise the need for horizontal cable managers while still ensuring optimum cable management and protection. In addition, the WBT angled patch panels are provided with rear cable management and support to ensure incoming cables are not overly stressed. Each port is numbered and pre-labelled which allows for easy identification. The modular configuration allows for easy installation and gradual expansion if required.

UTP OUTLETS FOR CATEGORY 6 AND CATEGORY 6A (UNSHIELDED)

Part Numbers: 66090017 (single port), 66090019 (dual port)


UTP outlets (telecommunication outlets) are designed to accept HY series category 6 and category 6A unshielded jacks. These outlets contain multiple cable entries and can be wall or surface mounted. Available in single or dual port configurations, they are an effective solution for providing an interface between horizontal cabling and equipment patch cords used in workstation areas.

STP OUTLETS FOR CATEGORY 6A (SHIELDED) – MODULAR SYSTEM

Part Numbers: 66090018 (single port)

Part Number: 66090020 (dual port)


STP outlets (telecommunication outlets) are designed to accept HY series category 6A shielded jacks. These outlets contain multiple cable entries and can be wall or surface mounted. Available in single or dual port configurations, they are an effective solution for providing an interface between horizontal cabling and equipment patch cords used in workstation areas.

CATEGORY 6 FLOOR DISTRIBUTOR, 8 PORTS (UNSHIELDED)

part Number: 66090023


The 8 port category 6 unshielded floor distributor, also known as a consolidation point (CP), provides great flexibility in office networks for easy Moves, Additions and Changes (MAC’s). It is an additional point in a permanent link, which allows for quick network modifications and is ideal for dynamic work environments.

FLOOR DISTRIBUTOR – MODULAR SYSTEM

Part Numbers: 66090021 (6 ports)

Part Number: 66090022 (12 ports)


The HY series 6 and 12 port floor distributors, also known as consolidation points (CP), provides great flexibility in office networks for easy Moves, Additions and Changes (MAC’s).
It is an additional point in a permanent link, which allows for quick network modifications and is ideal for dynamic work environments.

CATEGORY 6A UNSHIELDED PATCH CORDS, U/UTP, LSZH

Category 6A unshielded patch cords (U/UTP) allow for data transmission between patch panels, outlets and/or IT equipment.

Category 6A unshielded patch cords

CATEGORY 6A SHIELDED PATCH CORDS, S/FTP, LSZH

Category 6A shielded patch cords (S/FTP) allow for data transmission between patch panels, outlets and/or IT equipment. Shielded S/FTP patch cords feature an outer shielded braid, covering individually shielded pairs, providing optimum protection against EMI.

category 6a part numbers

DATA RACK, FRONT TO BACK DUCT FOR FIBRE CORDS, WITH TRUMPET OUTLETS

Part Number: TC1279-750KIT

This kit is installed from the front to the rear of a data rack, allowing fibre cords to be fed from front to back of the rack. The duct is supported by two sturdy metal mounting brackets fitted to the front and rear equipment mounting rails on either the left or right hand side; (4 x mounting screws and cage nuts are supplied). This kit occupies 2 RU of mounting space. The mounting brackets hold duct securing (“C”) brackets, which have 65mm of lateral adjustment. A length of 100mm x 50 mm duct carries the cords. It is supplied as a length of 800mm, which can be trimmed to suit the depth of the data rack. One end of the duct is slotted to accept a trumpet secured by a standard joiner. The other, (non-slotted), duct end is accurately cut to length and a trumpet is secured to the cut end of the duct using a slotless joiner.

DATA RACK, FRONT TO BACK DUCT FOR FIBRE CORDS, WITH ELBOW OUTLETS

Part Number: TC1279-536KIT

This 1RU kit is installed from the front to the rear of an equipment rack, allowing fibre cords to be fed from front to back of the rack. The duct is supported by two sturdy metal mounting brackets fitted to the front and rear equipment mounting rails (4 x mounting screws and cage nuts are supplied).  The mounting brackets hold duct securing (“C”) brackets, which have a little adjustment. A short length of 30mm x 30mm duct carries the cords. One end of the duct is slotted to accept a 900 down elbow, secured by a standard joiner. The other slotted duct end accepts a 90o horizontal  LH or RH elbow.

RACK TOP, DUCT FEEDING KIT, FOR A 1 METRE EQUIPMENT RACK

Part Number: PGTC1279-751KIT

The Duct Kit fits to a 1 metre deep Equipment Rack, and enables optical fibre cords to be fed from the front to rear of rack, either LHS or RHS. Mounting brackets and screws provided

MOUNTING RAIL ADAPTOR

Part Number: 66222027


The DIN rail mount adaptor allows for specialised mounting of HY Series RJ45 jacks and couplers. It is a practical solution where DIN mounting rails are present and is easy to install.

CABLE STRIPPING & TERMINATING TOOL

Part Number: 62×35


The HY series terminating tool allows for easy cable preparation and connector termination of HypaConnect HY series jacks. Easy to use and lightweight, this tool simplifies network deployment.

ELBOW, 90 DEGREES, M50 X 1.5

Data Rack Ducting & Accessories
See more

ELBOW, 90 DEGREES, M50 X 1.5

Part Number: TC1279-434 

This 90o Elbow is typically used to feed an optical fibre cable into a cabinet, after the cable has “broken-out” into several optical fibres. The Elbow is fastened to the cabinet using an M50 nut, after passing through a clearance hole. The lower end of the Elbow can accept either a 38mm dia cable ; or a Convoluted Tube, which houses the incoming optical fibre cable. The inner radius of the Elbow is 56mm, and the internal diameter is 41.5mm; so the Elbow can typically accept a cable of around 37/38mm dia

MOUNTING CLIP FOR METAL DUCTING FOR AN OVER THE TOP OUTLET

Part Number: TC1279-307S-2 

A pair of plastic mounting clips, enables an “Over the Top Outlet” to be located anywhere along a metal duct run. This enables optical fibre cords to leave the duct run at any position along its length, whilst maintaining the MBR at 30mm. The “Over the Top Outlet” allows 2.0mm dia optical fibre cords to “drop-off” the duct run and feed into 100mm x 100mm (FR) plastic duct and components. The “Over the Top Outlet” is Part No: TC1279-307A; and is available separately.