IN-LINE PRESSURISED CLOSURES
| W&BT P/N | Description | Max. Dia | Min. Dia | (L) Sheath Opening |
| 43300301 | Closure, In-Line Pressurised, 1000 62/15-350 | 62mm | 15mm | 350mm |
| 43300294 | Closure, In-Line Pressurised, 1000 62/15-500 | 62mm | 15mm | 500mm |
| 43300295 | Closure, In-Line Pressurised, 1000 92/30-500 | 92mm | 30mm | 500mm |
| 43300296 | Closure, In-Line Pressurised, 1000 122/38-650 | 122mm | 38mm | 650mm |
| 43300299 | Branch Off Kit – Use this kit (433/00299) with the above four closures | |||
| 43300297 | Closure, In-Line Pressurised, 1000 160/55-650 | 160mm | 55mm | 650mm |
| 43300367 | Closure, In-Line Pressurised, 1000 200/65-900 | 200mm | 65mm | 900mm |
| 43300300 | Branch Off Kit – Use this kit (433/00300) with the above two closures | |||
In stock
| W&BT P/N | Description | Max. Dia | Min. Dia | (L) Sheath Opening |
| 43300301 | Closure, In-Line Pressurised, 1000 62/15-350 | 62mm | 15mm | 350mm |
| 43300294 | Closure, In-Line Pressurised, 1000 62/15-500 | 62mm | 15mm | 500mm |
| 43300295 | Closure, In-Line Pressurised, 1000 92/30-500 | 92mm | 30mm | 500mm |
| 43300296 | Closure, In-Line Pressurised, 1000 122/38-650 | 122mm | 38mm | 650mm |
| 43300299 | Branch Off Kit – Use this kit (433/00299) with the above four closures | |||
| 43300297 | Closure, In-Line Pressurised, 1000 160/55-650 | 160mm | 55mm | 650mm |
| 43300367 | Closure, In-Line Pressurised, 1000 200/65-900 | 200mm | 65mm | 900mm |
| 43300300 | Branch Off Kit – Use this kit (433/00300) with the above two closures | |||
The 1000 In-Line Joint Closures are the preferred closure for all joints in the pressurised cable network including those on lead sheathed cables.
CLOSURE KIT CONTENTS:
- Heat-shrinkable sleeve
- Metal canister (2 halves)
- Flexible channels & clip
- Aluminium strips
- Cleaning tissues
- Abrasive strip
- Aluminium foil
- Valve nut & plug
- Shield continuity wire & Installation Instruct.
BRANCH CABLES:
The kit is designed for 1 cable entry, each end. Branched joints (more than 1 cable at an end) require use of one additional branching kit (S.433/00299 or S.433/00300) per added cable. Up to 4 cables, each end may be accommodated.
LEAD SHEATH CABLES:
Lead sheath cables entering heat-shrink material must be prepared correctly. This involves:
- Removing excess solder or scale from the sleeve bond-line area using a shave hook.
- Cleaning the bonding area by using a Cleaning Pad supplied in the kit.
- Fit a continuity wire across the joint opening – solder the wire to the lead sheath (resin core solder).
SCREEN CONTINUITY:
Use screen continuity wire, as supplied. Attach continuity clip to screen of MB sheath. With cables greater than 40mm dia. install 2nd continuity wire. Use type 3 kit, (S.433/00285) for 2nd continuity wire. For lead cables, clean lead sheath with shave hook. Protect joint with heat shield (S.513/00037). Strip approx.15mm insulation from end of continuity wire. Tin stripped wire & lead sheath. Solder wire to sheath using resin cored solder (S.004/00006).
CONNECTOR JOINTING:
Use standard connector jointing practises for In-Line Closures. Wrap completed joint bundle in 2 layers of craft paper (S.094/00002) – heat protection before installing canister.
INTERFACE JOINTS:
Use 1000 series closure for interface joints between Pressurised & Large Filled Cables. This allows cable pressurisation to protect the joint.


Reviews
There are no reviews yet.