Optical Fibre and Copper Cabling Systems

Telecom Outside Plant

Today, IDC technology has evolved for the outside plant. The availability of a tool-less modular block that is environmentally stable over very harsh conditions means that even furth erreliability gains can be realised in the future. In addition compatibility with current test cords and practices is ensured and the addition of protection devices is also available.Further to the internal connectivity capabilities the W&BT team has designed a number of additional features into this product with efficiency and ease of expandability being the main focus.

Showing all Telecom Outside Plant

DOME TESTER KIT

Closure Accessories
See more

DOME TESTER KIT

Part Number: 40003069dexgreen


Set of OJ covers used for pressure testing completed openable joints.

 

JOINTING KIT, HEAT SHRINKABLE

Part Number: 43300246


Jointing Kit, Heat shrinkable, Cable type: 2/0.40mm Lead Sheath-PIUT) to 2 pair (CPIUT & PEIUT) plastic

REMARKS: For use on lead sheath to plastic lead-in cable USE ONLY. Recommend closure.

NOTE: For jointing 2 pair/0.40 mm lead sheath lead-in cable. Aluminium foil used as a heat shield to protect the sheath during installation.

PBCS AIR BLOCKING CLOSURES

dexgreen

WBT P/N

NAME

DESCRIPTION 

51300196AIR BLOCK CLOSURE NO. 1Air Block Closure No. 1. PBCS 32/8, Heat Shrinkable Wrap-around Sleeve Kit.
51300197AIR BLOCK CLOSURE NO. 2Air Block Closure No. 2. PBCS 50/16, Heat Shrinkable Wrap-around Sleeve Kit.
51300208AIR BLOCK CLOSURE NO. 3Air Block Closure No. 3. PBCS 65/25, Heat Shrinkable Wrap-around Sleeve Kit.

Max. Cable Dia. 65mm.
Min. Cable Dia. 24mm.
Sheath Opening 200mm.
Length of Closure 500mm.

51300209AIR BLOCK CLOSURE NO. 4Air Block Kit Number No. 4.  PBCS 90/30, Heat Shrinkable Wrap-around Sleeve Kit.

Max. Cable Dia. 90mm,
Min. Cable Dia. 31mm,
Sheath Opening 230mm
Length of Closure 650mm.

SEALING TAPE

Closure Accessories
See more

SEALING TAPE

dexgreen

Part Number: 51300206


Purpose: To provide an adequate air/waterproof seal for damaged cables, pressurised, unpressurised and various other closures.

IN-LINE UNPRESSURISED CLOSURES

dexgreen

W&BT P/NDescriptionMax. DiaMin. Dia(L) Sheath Opening
51300187Closure, In-Line Unpressurised, No. 1, 43/8-10043mm8mm100mm
51300188Closure, In-Line Unpressurised, No. 2, 43/8-20043mm8mm200mm
51300189Closure, In-Line Unpressurised, No. 3, 75/15-25075mm15mm250mm
51300022Branch Off Kit (BOCL-S) – Use this kit (513/00022) with the above three closures
51300190Closure, In-Line Unpressurised, No. 4, 122/30-500122mm30mm500mm
51300097Branch Off Kit (BOCL-M) – Use this kit (513/00097) with the above closure

IN-LINE PRESSURISED CLOSURES

dexgreen

W&BT P/NDescriptionMax. DiaMin. Dia(L) Sheath Opening
43300301Closure, In-Line Pressurised, 1000 62/15-35062mm15mm350mm
43300294Closure, In-Line Pressurised, 1000 62/15-50062mm15mm500mm
43300295Closure, In-Line Pressurised, 1000 92/30-50092mm30mm500mm
43300296Closure, In-Line Pressurised, 1000 122/38-650122mm38mm650mm
43300299Branch Off Kit – Use this kit (433/00299) with the above four closures
43300297Closure, In-Line Pressurised, 1000 160/55-650160mm55mm650mm
43300367Closure, In-Line Pressurised, 1000 200/65-900200mm65mm900mm
43300300Branch Off Kit – Use this kit (433/00300) with the above two closures

CLOSURE, EXTRA SMALL

dexgreen

Part Number: 51300166


Extra Small O/J Closure. 80mm Dia. For up to 30/0.40mm cables designed for small pits and low pair count cables. Includes the closing / locking system, entry grommet, double O-ring cover seal.

 

CROSS CONNECT MODULAR PILLAR, 1800 PAIR

Part Number: TC2722-1800


Pillars or cross connect units are used to provide an accessible distribution/break-down point in the copper cable network between the exchange and the customer. They are fed by main copper cables from the exchange that in turn feed smaller size outgoing customer distribution cables. The connected copper cable pairs are used to provide a telecommunication service to customers.
The 1800 pair pillar will typically feed a distribution area of up to 600 customers (maximum).

The pillar provides an access and test point in the network as the customer circuit can be tested both back to the exchange and forward to the customers residence, if ever the line develops a fault. Typically, a ratio of about 1:2 is provided between main exchange pairs and customer distribution pairs of copper cables.

IDS TERMINATION TOOL

Part Number: 43000117


  • Terminating Tool. Standard, Insulation Displacement System (IDS).
  • Suitable for terminating cable onto Quante termination unit modules.
  • SID connection tool. SID for standard cable insertion tool.
  • Cable slack and insertion guide.
  • Built-in pull-up hook.

EARTH BOND WIRE KIT

Part Number: 43000139


Earth bond wire kit for 900 pair and 1800 pair pillar cross connect unit.

900 TO 1800 PAIR CONVERSION KIT

Part Number: TC2722-03KIT


Conversion kit. 900 pair to 1800 pair, IDS.

This kit allows for the modification and expansion of a 900 pair pillar.

It allows for increasing the capacity of a 900 pair pillar to 1800 pair capacity.

FERRULE KIT

Copper Pillars
See more

FERRULE KIT

Part Number: TC2722-100EKIT

 

Also available: TC2722-100EK-10 (ferule kit, pack of 10).

SEALING PLUG

Copper Pillars
See more

SEALING PLUG

Part Number: TC2722-07


Sealing plug and O-Ring kit

Also available: TC2722-36 – Sealing plug.

ROUND GROUND GASKET

Part Number: TC2722-35

Ground gasket, round, malthoid.

CENTRE COLUMN ASSEMBLY

Part Number: TC2722-17 Part Number: TC2722-18
Centre column assembly, 900 pair pillar

Replacement item in 900 pair pillar (TC2722-900).

Centre column assembly, 1800 pair pillar

Replacement item in 1800 pair pillar (TC2722-1800).

CENTRE STUD

Copper Pillars
See more

CENTRE STUD

Part Number: TC2722-01

Centre stud.

RUBBER SEAL

Copper Pillars
See more

RUBBER SEAL

Part Number: TC2722-66Part Number: TC2722-37 
Rubber sealing for 300 pair pillar cover.Rubber Sealing for 900 pair and 1800 pair pillar cover.
Looking for a tailored solution? Call us today.